Optical Spectroscopic Detection of Mitochondrial Biomarkers (FMN and NADH) for Hypothermic Oxygenated Machine Perfusion: A Comparative Study in Different Perfusion Media

Cadinu, Lorenzo Agostino
First
Investigation
;
Ricci, Pier Carlo
Supervision
;
Barbaro, Massimo
Last
Funding Acquisition
2025-01-01

Abstract

Highlights: What are the main findings? First systematic optical characterization of FMN/NADH in clinically relevant perfusion media, revealing medium-specific fluorescence quenching effects. Identification of critical sensor design parameters: optimal excitation wavelengths (FMN: 455 nm; NADH: 360 nm), concentration-dependent NADH nonlinearity (>100 µg mL−1), and FMN-NADH spectral interference. What is the implication of the main finding? Providing standardized calibration protocols enabling direct translation to portable optical sensors for real-time perfusion monitoring. Providing the theoretical framework to develop portable optical sensors for clinical perfusion monitoring, with specific guidelines for excitation wavelengths, interference mitigation, and medium-specific calibration. Ex situ machine perfusion has emerged as a pivotal technique for organ preservation and pre-transplant viability assessment, where the real-time monitoring of mitochondrial biomarkers—flavin mononucleotide (FMN) and nicotinamide adenine dinucleotide (NADH)—could significantly mitigate ischemia-reperfusion injury risks. This study develops a non-invasive optical method combining fluorescence and UV-visible spectrophotometry to quantify FMN and NADH in hypothermic oxygenated perfusion media. Calibration curves revealed linear responses for both biomarkers in absorption and fluorescence (FMN: λex = 445 nm, λem = 530–540 nm; NADH: λex = 340 nm, λem = 465 nm) at concentrations < 100 μg mL−1. However, NADH exhibited nonlinear fluorescence above 100 μg mL−1, requiring shifted excitation to 365 nm for reliable detection. Spectroscopic analysis further demonstrated how perfusion solution composition alters FMN/NADH fluorescence properties, with consistent reproducibility across media. The method’s robustness was validated through comparative studies in clinically relevant solutions, proposing a strategy for precise biomarker quantification without invasive sampling. These findings establish a foundation for real-time, optical biosensor development to enhance organ perfusion monitoring. By bridging spectroscopic principles with clinical needs, this work advances translational sensor technologies for transplant medicine, offering a template for future device integration.
2025
Inglese
25
13
4031
21
Esperti anonimi
internazionale
scientifica
mitochondrial molecular biomarkers; spectroscopy application; optic phenomena in perfusion solution; spectroscopic calibration; methodologies and protocols; optic sensor theoretical foundations
Goal 3: Good health and well-being
Cadinu, Lorenzo Agostino; Sun, Keyue; Jiao, Chunbao; Panconesi, Rebecca; Satish, Sangeeta; Yildirim, Fatma Selin; Karakaya, Omer Faruk; Wehrle, Chase ...espandi
1.1 Articolo in rivista
info:eu-repo/semantics/article
1 Contributo su Rivista::1.1 Articolo in rivista
262
18
open
Files in This Item:
File Size Format  
2025-cadinu-sensors-25-04031.pdf

open access

Type: versione editoriale
Size 5.65 MB
Format Adobe PDF
5.65 MB Adobe PDF View/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Questionnaire and social

Share on:
Impostazioni cookie